2018/02/28

乐泰胶水loctite7218应用

乐泰胶水loctite7218应用

乐泰胶水loctite7218应用:

本文来自:汉高乐泰胶水(中国)有限公司 Henkel Loctite官网 www.loctite.net/c1249.html 

TechnicalDataSheet

    LOCTITE® Nordbak®

    Wearing Compound™

    January-2007PRODUCTDESCRIPTION    TYPICALPROPERTIESOFUNCUREDMATERIAL

    ®    ®    Resin:

LOCTITE  Nordbak  WearingCompound™  provides  the

    WeightPerGallon,lbs/gal    17.9 to18.8LMS

followingproductcharacteristics:

Technology    Epoxy    Hardener:

ChemicalType    Epoxy    LMS

    LMS    WeightPerGallon,lbs/gal    18.7 to18.8

Appearance(Resin)    Gray

Appearance(Hardener) DarkgrayLMS

Components    Two component - requiresmixing    Mixed:

    GelTime@70°C, minutes    13 to24LMS

MixRatio,byvolume-  2:1    Coverage    0.8 m²@0.63 cmthick/25 lbResin:Hardener

MixRatio,byweight-   2:1    FlashPoint-SeeMSDS

Resin:Hardener

Cure    Roomtemperaturecure

Application    Abrasionresistance

SpecificApplication    ● Cycloneandseparatorbodies    TYPICALCURINGPERFORMANCE

    ● Dustcollectorsandexhausters

    ● Pumplinersandimpellers    CuringProperties

    ● Fanbladesandhousings    WorkingTime @25°C, minutes    30

    ● Chutesandhoppers    CureTime @25°C, hours    7

    ● Elbowsandtransitionpoints

SpecificBenefit    ● Ceramic-filledforoutstanding    TYPICALPROPERTIESOFCUREDMATERIAL

    resistancetoabrasion

    ● Renews worn surfaces fast -    Cured @ 25 °C

    reducesdowntime    PhysicalProperties:

    ● Extends wear  life  -  resists    Compressive Strength,ISO604    N/mm²  110.3

    sliding  abrasive  wear  and    (psi)       (16,000)

    eliminates  costly  wear  part    ShoreHardness, ISO868,Durometer D    90

    inventory

    ● Non sag - provides abrasion    GENERALINFORMATION

    resistance on over-head and    Thisproductisnotrecommendedforuseinpureoxygen

    verticalsurfaces    and/oroxygenrichsystemsandshouldnotbeselectedas

    asealantforchlorineorotherstrongoxidizingmaterials.

    ®    ®    Forsafehandlinginformationonthisproduct,consulttheLOCTITE  Nordbak  Wearing Compound™  is a two-part    MaterialSafetyDataSheet(MSDS).

ceramicfilledepoxypastedesignedtoprotect, rebuildand

repairhighwearareasofprocessingequipment. Temperature

range-28°Cto+121°C.    Directionsforuse

    SurfacePreparation

    Proper surface preparation is critical to the long-term

    performanceofthisproduct. Theexactrequirementsvarywith

    theseverityoftheapplication,expectedservicelife,andinitial

    substrateconditions.

    1. Thoroughly clean and abrade surfaces (grit blast if

    possible),finallycleanwithLOCTITE®7063™.Themore

    thoroughthedegreeofsurfacepreparationthebetterthe

    performanceoftheapplication.

    2. Onverticaloroverheadareas,itisrecommendedtotack

    expandedmetalmeshtosubstratebeforeapplicationof

    LOCTITE®Nordbak®WearingCompound™ .    TDSLOCTITE®Nordbak WearingCompound™ ,  January-2007®

Mixing:    Storage

 1. Measure2partsresinto1parthardener byvolumeor    Storeproductintheunopenedcontainer inadry location.

   weight,transfer entirekitontoacleananddrymixing    Materialremovedfromcontainersmaybecontaminatedduring

   surfaceandmixtogetheruntiluniformincolor.    use.  Do not return liquid to original container.  Storage2. Ifresinandhardenertemperaturesare 15°Corbelow,    informationmaybeindicatedontheproductcontainerlabeling.

    preheatresinonlytoabout 32°C but not to exceed    OptimalStorage: 8°Cto21°C. Storagebelow 8°Cor

    38°C.    greaterthan28°Ccanadverselyaffectproductproperties.

    Henkel cannotassumeresponsibilityfor product whichhasApplicationMethod:    beencontaminatedor stored under conditions other than1. Applyfullymixedmaterialtothepreparedsurface.    those recommended. If additional information is required,2. Initiallyapplyasathinfilmto"wet"outthesurface.    please contact your local Technical Service Center or3. Builduptodesiredthickness(minimum6mm),avoidair    CustomerServiceRepresentative.

    entrapment.

 4. At  25°Cworkingtimeis 30 minutesandfunctionalcure   Note

    timeis7 hours.    Thedatacontainedhereinarefurnishedfor informationonlyCaution:  Useanapproved, positive-pressure, supplied air    and are believed to be reliable.  We cannot assumerespirator  when  welding  or  torch  cutting  near  cured    responsibilityfortheresultsobtainedby othersover whosecompound.  DoNotuseopenflameoncompound.    methodswehavenocontrol. Itistheuser'sresponsibilityto

    determinesuitabilityfortheuser'spurposeofanyproduction

    methodsadmveisntiolnefdrhtereeinroatndtitonaodfopprtsurcthprecafutionrssoasTechnicalTipsforWorkingWithEpoxies    againstanyhazardsthatmaybeinvolvedinthehandlingandWorkingtimeandcuredependsontemperatureandmass:    usethereof. Inlight of theforegoing, HenkelCorporation● Thehigherthetemperature,thefasterthecure.    specificallydisclaimsallwarrantiesexpressedorimplied,● Thelargerthemassofmaterial,thefasterthecure.    including warrantiesof merchantabilityor fitnessfor aTospeedthecureofepoxiesatlowtemperatures:    particular purpose, arising fromsaleoruseof Henkel● Storeepoxyatroomtemperature.    Corporation’sproducts.  HenkelCorporationspecifically● Pre-heatrepairsurfaceuntilwarmtothetouch.    disclaims any liability for consequential or incidentalToslowthecureofepoxiesat hightemperatures:    damagesofanykind,includinglostprofits. Thediscussion● Mixepoxyinsmallmassestopreventrapidcuring.    ihetrerinretofdvariousrepresentationprocesses orthatcomptohsitionsreisfreenot tofrombe● Coolresin/hardenercomponent(s).    dominationofpatentsownedbyothersorasalicenseunder

    any Henkel  Corporation patents that may cover  such

    processes or compositions.  We recommend that eachLoctiteMaterialSpecificationLMS    prospectiveusertesthisproposedapplicationbeforerepetitiveLMSdatedJuly-03,2001(Resin)andLMSdatedJuly-03,2001    use,usingthisdataasaguide. Thisproductmaybecovered(Hardener).Testreportsforeachbatchareavailableforthe    byoneormoreUnitedStatesor foreignpatents or patentindicatedproperties. LMStestreportsincludeselectedQCtest    applications.

parameters considered appropriate to specifications for

customer use. Additionally, comprehensive controls are in    Trademarkusage

place to assure product quality and consistency. Special

customer specification requirements may be coordinated    Exceptasotherwisenoted,alltrademarksinthisdocumentthroughHenkelLoctiteQuality.    are  trademarks of  Henkel Corporation in the U.S. and

    elsewhere.   ® denotes atrademarkregisteredintheU.S.Conversions    PatentandTrademarkOffice.

(°Cx1.8)+32=°F

kV/mmx25.4=V/mil

mm/25.4=inches    Reference0.0

µmx/2.5.4=mlbil

N/mmx5.71=lb/in

N/mm²x145=psi

MPax145=psi

N·m x 8.851= lb·in

N·mx0.738=lb·ft

N·mm x0.142=oz·in

mPa·s=cP

HenkelLoctiteAmericas    HenkelLoctiteEurope    HenkelLoctiteAsiaPacific+860.571.5100    +49.89.9268.0    +86.20.3623.0506

    Forthemostdirectaccesstolocalsalesandtechnicalsupportvisit:www.loctite.net

上一页:乐泰胶水LOCTITE EA 907Hysol应用