TechnicalDataSheet
LOCTITE® Nordbak®
Wearing Compound™
January-2007PRODUCTDESCRIPTION TYPICALPROPERTIESOFUNCUREDMATERIAL
® ® Resin:
LOCTITE Nordbak WearingCompound™ provides the
WeightPerGallon,lbs/gal 17.9 to18.8LMS
followingproductcharacteristics:
Technology Epoxy Hardener:
ChemicalType Epoxy LMS
LMS WeightPerGallon,lbs/gal 18.7 to18.8
Appearance(Resin) Gray
Appearance(Hardener) DarkgrayLMS
Components Two component - requiresmixing Mixed:
GelTime@70°C, minutes 13 to24LMS
MixRatio,byvolume- 2:1 Coverage 0.8 m²@0.63 cmthick/25 lbResin:Hardener
MixRatio,byweight- 2:1 FlashPoint-SeeMSDS
Resin:Hardener
Cure Roomtemperaturecure
Application Abrasionresistance
SpecificApplication ● Cycloneandseparatorbodies TYPICALCURINGPERFORMANCE
● Dustcollectorsandexhausters
● Pumplinersandimpellers CuringProperties
● Fanbladesandhousings WorkingTime @25°C, minutes 30
● Chutesandhoppers CureTime @25°C, hours 7
● Elbowsandtransitionpoints
SpecificBenefit ● Ceramic-filledforoutstanding TYPICALPROPERTIESOFCUREDMATERIAL
resistancetoabrasion
● Renews worn surfaces fast - Cured @ 25 °C
reducesdowntime PhysicalProperties:
● Extends wear life - resists Compressive Strength,ISO604 N/mm² 110.3
sliding abrasive wear and (psi) (16,000)
eliminates costly wear part ShoreHardness, ISO868,Durometer D 90
inventory
● Non sag - provides abrasion GENERALINFORMATION
resistance on over-head and Thisproductisnotrecommendedforuseinpureoxygen
verticalsurfaces and/oroxygenrichsystemsandshouldnotbeselectedas
asealantforchlorineorotherstrongoxidizingmaterials.
® ® Forsafehandlinginformationonthisproduct,consulttheLOCTITE Nordbak Wearing Compound™ is a two-part MaterialSafetyDataSheet(MSDS).
ceramicfilledepoxypastedesignedtoprotect, rebuildand
repairhighwearareasofprocessingequipment. Temperature
range-28°Cto+121°C. Directionsforuse
SurfacePreparation
Proper surface preparation is critical to the long-term
performanceofthisproduct. Theexactrequirementsvarywith
theseverityoftheapplication,expectedservicelife,andinitial
substrateconditions.
1. Thoroughly clean and abrade surfaces (grit blast if
possible),finallycleanwithLOCTITE®7063™.Themore
thoroughthedegreeofsurfacepreparationthebetterthe
performanceoftheapplication.
2. Onverticaloroverheadareas,itisrecommendedtotack
expandedmetalmeshtosubstratebeforeapplicationof
LOCTITE®Nordbak®WearingCompound™ . TDSLOCTITE®Nordbak WearingCompound™ , January-2007®
Mixing: Storage
1. Measure2partsresinto1parthardener byvolumeor Storeproductintheunopenedcontainer inadry location.
weight,transfer entirekitontoacleananddrymixing Materialremovedfromcontainersmaybecontaminatedduring
surfaceandmixtogetheruntiluniformincolor. use. Do not return liquid to original container. Storage2. Ifresinandhardenertemperaturesare 15°Corbelow, informationmaybeindicatedontheproductcontainerlabeling.
preheatresinonlytoabout 32°C but not to exceed OptimalStorage: 8°Cto21°C. Storagebelow 8°Cor
38°C. greaterthan28°Ccanadverselyaffectproductproperties.
Henkel cannotassumeresponsibilityfor product whichhasApplicationMethod: beencontaminatedor stored under conditions other than1. Applyfullymixedmaterialtothepreparedsurface. those recommended. If additional information is required,2. Initiallyapplyasathinfilmto"wet"outthesurface. please contact your local Technical Service Center or3. Builduptodesiredthickness(minimum6mm),avoidair CustomerServiceRepresentative.
entrapment.
4. At 25°Cworkingtimeis 30 minutesandfunctionalcure Note
timeis7 hours. Thedatacontainedhereinarefurnishedfor informationonlyCaution: Useanapproved, positive-pressure, supplied air and are believed to be reliable. We cannot assumerespirator when welding or torch cutting near cured responsibilityfortheresultsobtainedby othersover whosecompound. DoNotuseopenflameoncompound. methodswehavenocontrol. Itistheuser'sresponsibilityto
determinesuitabilityfortheuser'spurposeofanyproduction
methodsadmveisntiolnefdrhtereeinroatndtitonaodfopprtsurcthprecafutionrssoasTechnicalTipsforWorkingWithEpoxies againstanyhazardsthatmaybeinvolvedinthehandlingandWorkingtimeandcuredependsontemperatureandmass: usethereof. Inlight of theforegoing, HenkelCorporation● Thehigherthetemperature,thefasterthecure. specificallydisclaimsallwarrantiesexpressedorimplied,● Thelargerthemassofmaterial,thefasterthecure. including warrantiesof merchantabilityor fitnessfor aTospeedthecureofepoxiesatlowtemperatures: particular purpose, arising fromsaleoruseof Henkel● Storeepoxyatroomtemperature. Corporation’sproducts. HenkelCorporationspecifically● Pre-heatrepairsurfaceuntilwarmtothetouch. disclaims any liability for consequential or incidentalToslowthecureofepoxiesat hightemperatures: damagesofanykind,includinglostprofits. Thediscussion● Mixepoxyinsmallmassestopreventrapidcuring. ihetrerinretofdvariousrepresentationprocesses orthatcomptohsitionsreisfreenot tofrombe● Coolresin/hardenercomponent(s). dominationofpatentsownedbyothersorasalicenseunder
any Henkel Corporation patents that may cover such
processes or compositions. We recommend that eachLoctiteMaterialSpecificationLMS prospectiveusertesthisproposedapplicationbeforerepetitiveLMSdatedJuly-03,2001(Resin)andLMSdatedJuly-03,2001 use,usingthisdataasaguide. Thisproductmaybecovered(Hardener).Testreportsforeachbatchareavailableforthe byoneormoreUnitedStatesor foreignpatents or patentindicatedproperties. LMStestreportsincludeselectedQCtest applications.
parameters considered appropriate to specifications for
customer use. Additionally, comprehensive controls are in Trademarkusage
place to assure product quality and consistency. Special
customer specification requirements may be coordinated Exceptasotherwisenoted,alltrademarksinthisdocumentthroughHenkelLoctiteQuality. are trademarks of Henkel Corporation in the U.S. and
elsewhere. ® denotes atrademarkregisteredintheU.S.Conversions PatentandTrademarkOffice.
(°Cx1.8)+32=°F
kV/mmx25.4=V/mil
mm/25.4=inches Reference0.0
µmx/2.5.4=mlbil
N/mmx5.71=lb/in
N/mm²x145=psi
MPax145=psi
N·m x 8.851= lb·in
N·mx0.738=lb·ft
N·mm x0.142=oz·in
mPa·s=cP
HenkelLoctiteAmericas HenkelLoctiteEurope HenkelLoctiteAsiaPacific+860.571.5100 +49.89.9268.0 +86.20.3623.0506
Forthemostdirectaccesstolocalsalesandtechnicalsupportvisit:www.loctite.net