乐泰胶水LOCTITE341现场施工工艺应用
乐泰胶水LOCTITE341现场施工工艺应用:
本文来自:汉高乐泰胶水(中国)有限公司 Henkel Loctite官网 www.loctite.net/c1261.html
Product Description Sheet

10o0c1 T roiullt, Bro 0o6k C6ro-3s9sin0g
Telephone: (860) 571-5100 Product 341
FAX: (860) 571-5465 Industrial Products, January 1999PRODUCT DESCRIPTION PHYSICAL PROPERTIES OF CURED MATERIAL AND
® OPERATING PARAMETERS
LOCTITE Product 341 is a two-part, toughened acrylic Time to achieve full strength on steel @ 22ºC (0.05 mm) hours:adhesive intended for structural bonding of steel parts. It
fixtures at room temperature when mixed, but attains full Coefficient of Thermal Expansion, ASTM D 696, 1/ºK 100 x 10-6strength only when exposed to temperatures above 90ºC. It is Coefficient of Thermal Conductivity, ASTM C 177, W
intended for use in applications where the completed assembly m.ºK 0.1is subsequently subjected to a paint bake cycle at temperatures Specific Heat, kJ
up to 200ºC. kg. ºK 0.3
Recommended gap, mm 0.05TYPICAL APPLICATIONS Maximum gap, mm 3.0Product 341 is suitable for bonding structural or sheet steel
where some continuous or repeated loading is encountered. PERFORMANCE OF CURED MATERIAL
Examples are metal furniture, doors or vehicle bodies. It is After 24 hours @ 22ºC + 30 mins. 185ºC
capable of bonding through many commonly-used protective Shear Strength, ASTM D 1002
wax or oil coatings. DIN 53283, N/mm2 6 to 16PROPERTIES OF UNCURED MATERIAL N.B. Ranges are based on mean
Typical Value
Chemical Type Elastomer/methacrylate NOTE: All data is generated on degreased substrates. ProductAppearance Clear yellow 341 has the ability to bond through most protective oils typicallySpecific Gravity 0.96 used on “as received” steel. Strength and speed of cure will beViscosity @ 25ºC, mPa.s affected depending on the grade of oil and quantity present.Broinoklfie ld5 RV T20 RPM 120,000 to 200,000 Testing is recommended to determine actual strength and cureDIN 54453, mPa.s speed for any given substrate condition.
D=20 1/S
After t=180 100,000 to 200,000
Flash Point, COC, ºC 82 TYPICAL ENVIRONMENTAL RESISTANCE
CURING PERFORMANCE Hot Strength
Cure Speed vs. Bond Gap Strength Test Procedure: ASTM D 1002, DIN 53283Figure 1 shows the rate of cure through different gaps. These Substrate: Grit blasted mild steel
tests were made on steel lap shear specimens. Test procedure Cure Procedure: 30 minutes @ 185ºC
in accordance with ASTM D 1002 and DIN 53283. The
development of tensile shear strength provided a measurement
of the rate of cure. 100
75
100
T 50
t 75
a
g 0.05 25
n
r 50
t
l 0 50 100
a 150i 25
t
n Temperature,°C
I
0 12 hr. 24 hr. 48 hr. Heat Aging
5 min 10 min 30 min 1 hr. 3 hr. 6 hr.
Strength Test Procedure: ASTM D 1002, DIN 53283
Substrate: Grit blasted mild steel
Cure Procedure: 30 minutes @ 185ºC
THE TECHNICAL DATA CONTAINED HEREIN ARE INTENDED AS REFERENCE ONLY.NOT FOR PRODUCT SPECIFICATIONS
PLEASE CONTACT LOCTITE CORPORATION QUALITY DEPARTMENT FOR ASSISTANCE AND RECOMMENDATIONS ON SPECIFICATIONS FOR THIS PRODUCT.
ROCKY HILL, CT FAX: +1 (860)-571-5473 DUBLIN, IRELAND FAX: +353-(1)-451 - 9959
PDS Product 341, January 1999100 Note
T 120°C
R The data contained herein are furnished for information only andt are believed to be reliable. We cannot assume responsibility fora 150°C
d the results obtained by others over whose methods we have noe75
r control. It is the user's responsibility to determine suitability fors
e the user's purpose of any production methods mentioned hereinM50
h and to adopt such precautions as may be advisable for thet protection of property and of persons against any hazards thatg
re25 may be involved in the handling and use thereof. In light of thet
l foregoing, Loctite Corporation specifically disclaims allia warranties expressed or implied, including warranties oft
n merchantability or fitness for a particular purpose, arisingI 0 1000 2000 3000 4000 5000
Hours from sale or use of Loctite Corporation’s products. Loctite
Corporation specifically disclaims any liability forChemical / Solvent Resistance consequential or incidental damages of any kind, includingStrength Test Procedure: ASTM D 1002, DIN 53283 lost profits. The discussion herein of various processes orSubstrate: “Astrolan” coated steel compositions is not to be interpreted as representation that theyCure Procedure: 30 minutes @ 185ºC are free from domination of patents owned by others or as aAging Period: 2 weeks license under any Loctite Corporation patents that may cover
such processes or compositions. We recommend that each
prospective user test his proposed application before repetitive
Solvent Temp. % Initial Strength retained use, using this data as a guide. This product may be coveredMotor Oil 80ºC 80 by one or more United States or foreign patents or patentPetrol 22ºC 30 applications.
Brake Fluid 22ºC 100
95% RH 40ºC 100
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Material Safety Data Sheet, (MSDS).
Storage
Products shall be ideally stored in a cool, dry location in
unopened containers at a temperature between 8° to 28°C
(46° to 82°F) unless otherwise labeled. Optimal storage is at the
lower half of this temperature range. To prevent contamination
of unused product, do not return any material to its original
container. For specific shelf-life information, contact your local
Technical Service Center.
Data Ranges
The data contained herein may be reported as a typical value
and/or range. Values are based on actual test data and are
verified on a periodic basis.